Anaesthetics Healthcare Equipment

salesaipl1951@gmail.com

+(91) - 9820045383

01

Anaesthesia Apparatus

Anesthesia Apparatus & Accessories offered are known for delivering precision functionality in involved medical procedures. Here, we ensure these matches up to the industry standards and feature innovative design standards which make these easy to use as well as also deliver longer service life standards. We can make these available in different finish specifications so as to precision accommodate different operating procedures. The range offered by us under this category include Rotameter Units, Yokes, Emergency Oxygen Units, Oxygen Failure Alarm, Goldman Halothane Vaporizer, Change Over Units, Preset Regulators, Cut off Regulators, Cylinder Conversion Units - Oxygen and Cylinder Conversion Units - Nitrous Oxide.

» Rotameter Units

 

Rotameter Units offered are made available by us in different finish specifications to choose from. The range includes Rotameter Unit (without tubes) where the differential pressure ‘P’ is created in main flow through Orifice plate in main pipeline that creates branch of flow moving through By-Pass line provided across orifice plate from upstream side to downstream side of Orifice Plate. Further, additional Orifice plate is also provided in By-Pass line designed in a way that creates flow through Orifice plate flows in proportion with flow through main orifice plate, thus allowing measurement of flow from By Pass line as well as allowing estimation of flow from main pipe line. Other than this, we also offer Rotameter Tube & Bobbin that comprises dual tapered calibrated tube at 20OC & 1013mbar abs. Further, the Bobbin Float features aluminum alloy anodized red finish with silver dot so as to provide for easy observation of rotation. Here, the operation of tubes can be confirmed through checking location of flowmeter bobbin as well as through observing rotation of the bobbin.

Specifications : Rotameter Unit (Without Tubes) :Image

Model No. Volume Range
3700 Accommodates one 230mm tube
3600 Accommodates two 230mm tube
3500 Accommodates three 230mm tube

 

Rotameter Tube & Bobbin:

Model No. Volume Range
3601 Oxygen 0.1 to 10.0 ltr/min,100 to 10000 cc/min
3602 Nitrous Oxide 0.2 to 12.0 ltr/min , 200 to 12000 cc/min
3612 Air 0.1 to 12.0 ltr/min , 100 to 12000 cc/min
3613 Oxygen 0 to 1.0 ltr/min , 0 to 1000 cc/min
Enquiry

» Yokes

Image

Yokes offered are made available by us in different finish models so as to precisely match up to the demands of the customers. The range includes Yoke - Economy Model which are made available in options of 3652 - Oxygen and 3653 - Nitrous Oxide finish. These are made available in color coded plastic cover with other support components featuring stainless steel finish so as to avoid rusting. It is also pin indexed for use on anesthesia trolley. Other than this, Yoke - Compact Model offered is available in two models - 3650 - Oxygen and 3651 - Nitrous Oxide. The construction includes single piece brass chromed finish that is pin indexed for use on anesthesia trolley. Apart from these, one another model being offered includes Yoke – Midget that finds application in ambulances, mines, domiciliary use, airports, medical disaster situations, railways and other areas. These are available in range including 3654 - Oxygen for use with F. A. Valve, 3655 - Nitrous Oxide and 3656 - Oxygen for use with Rao’s Regulator.

Specifications : Yoke - Economy Model :

Model No. Volume Range
3652 Oxygen
3653 Nitrous Oxide

Yoke - Compact Model :
Model No. Volume Range
3650 Oxygen
3651 Nitrous Oxide

Yoke – Midget :
Model No. Volume Range
3654 Oxygen for use with F. A. Valve
3655 Nitrous Oxide
3656 Oxygen for use with Rao’s Regulator

Applications :
  • Domiciliary use
  • Ambulances
  • Mines
  • Airports
  • Railways
  • Medical disaster situations
Enquiry

» Emergancy Oxygen Units

Image

Emergency Oxygen Units offered comprise an important accessory that finds usage in Gas Anesthesia Equipment. The range includes non-return valves assembly with button that allows for flushing circuit with oxygen in emergencies. Here, we ensure these feature precision design and construction standards so as to deliver optimum functional support in given applications. Further, we also constantly upgrade the base models of the product so as to ensure these best match with the procedure as well as provide ease of usage.

Features:
  • Precision designed range of Emergency Oxygen Units
  • Used as an important accessory used in Gas Anesthesia Equipment
  • Incorporates non-return valves assembly
  • Also features button for flushing circuit with oxygen
Enquiry

» Oxygen Failure Alarm

Image

Oxygen Failure Alarm offered comprises precision designed and constructed range of O2 Failure Alarms for gas used in Anesthesia Apparatus. Providing functionality support as a battery operated controlled device, the offered alarm system is used in analyzing oxygen pressure and works as pneumatically controlled device that activates audio alarm for around fifteen seconds of time duration in cases where oxygen pressure in system falls to approximately 4.2kg/cm2.

Features:
  • Precision designed range of Oxygen Failure Alarms
  • Used for gas used in Anesthesia apparatus
  • Battery operated controlled device used in analyzing oxygen pressure
  • Battery operated pneumatically controlled device that activates audio alarm for around fifteen seconds in cases where oxygen pressure in system falls to approximately 4.2kg/cm2
Enquiry

» Goldman Halothane Vaporizer

Image

Goldman Halothane Vaporizer offered is made available by us in without stand finish. For delivering efficient and precise functional support in defined processes, the vaporizer system comes with provision of vaporizing chamber available in form of glass bowl or bottle that contains liquid anesthetic as well as a tap which helps in controlling proportion of gas that flows through it. Being drawover type vaporizer, its precision designs limit maximum concentration of Halothane vapor to 3% by volume. This is achieved irrespective of total gas flow provided through unit. Further, the system also allows adjustment through means of ratchet type control valve. The unit also features glass jar being screwed on body and allows quick detachment for easy filling. Further, the vaporizer is also suitable with Trichloroethylene in low concentration.

Features:
  • Optimum functionality based Goldman Halothane Vaporizers
  • Are made available in without stand finish
  • Vaporizers comprises vaporizing chamber including glass bowl/bottle that contains liquid anesthetic as well as a tap that controls proportion of gas flowing through it
  • Drawover type finish
  • Designed for limiting maximum concentration of Halothane vapour to 3% (this is achieved irrespective of total gas flow through unit)
  • Adjustment made using ratchet type control valve
  • Glass jar screwed to body with quick detachment possibilities for easy filling
  • Vaporizer also suitable for use with Trichloroethylene in low concentration Enquiry

» Change Over Units

Image

Change Over Units offered is made available by us in precision designed and constructed finish and finds usage in Anesthesia Gas Apparatus. These change over units come normally positioned at top of apparatus table and feature built-in emergency oxygen push button as well as provision of change over facility from open to closed circuit as well as from closed to open position. Here, we ensure the offered products are made available in precision design and construction standards so as to best match up with the defined operational demands. 

Features:
  • Precision designed and optimum functionality based Change Over Units
  • Finding application in Anesthesia Gas Apparatus
  • Change Over Unit positioned at top of apparatus table
  • Change Over Unit features built-in emergency oxygen push button as well as change over facility from open to closed circuit
  • Change Over Unit features built-in emergency oxygen push button as well as change over facility from closed circuit to open circuit

» Preset Regulators

Image

Preset Regulators offered comprises Rao's Preset Regulator that is made available by us in different operational finishes including in meeting the handling demands of oxygen & Nitrous Oxide gases used in anesthesia applications. Designed and developed for anesthesia apparatus only, these come with outlets featuring non-return valves so as to ensure there is not back flow of gases. Further, safety valve is also incorporated in unit, thus avoiding need of safety valve in tubing between regulator and rotameter unit. The models offered include 3625 - Oxygen and 3626 - Nitrous Oxide. 

Features:
  • Precision designed range of Rao’s Preset Regulators
  • Made available in two variants - Oxygen & Nitrous Oxide
  • Finding application in anesthesia apparatus only
  • Outlets feature use if non-return valves for avoiding back flow of gases
  • Finish options comprise 3625 - Oxygen and 3626 - Nitrous Oxide
  • Safety valve is incorporated in unit, thus these do not require safety valve in tubing between regulator and rotameter unit

» Cut off Regulators

Image

Cut off Regulators offered comprises Rao’s Cut Off Regulators which are made available with safety valve that is incorporated in unit, thus allowing no use of safety valve in tubing between regulator as well as the rotameter unit. Finding application in Rotameter units, the operators should ensure that Nitrous Oxide Regulators are activated only in cases where Oxygen Regulators are pressurized, thus minimizing risk attached of administering Nitrous Oxide in absence of Oxygen. 

Features:
  • Rao’s Precision engineered range of Cut off Regulators
  • Finding application in Rotameter units
  • The safeguard step includes to activate Nitrous Oxide Regulators only in event of Oxygen Regulators being pressurized, thus minimizing risk of administering Nitrous Oxide in absence of Oxygen
  • Unit comprises input of safety valve to ensure secure functioning
  • These units do not require safety valve in tubing between regulator & rotameter unit Enquiry

» Cylinder Conversion Units - Oxygen

Image

Cylinder Conversion Units - Oxygen offered comprises Rao’s Bulk Cylinder Conversion Units that find application for connecting bulk cylinders to anesthesia apparatus. We can make these available in two different finish types including 3675 – Oxygen. These conversion units find usage in connecting bulk cylinders to anesthesia apparatus. The complete unit comprises Regulator, a Pin Index Adaptor to fit on yoke of apparatus in place of service cylinder and 2 mtrs. High Pressure Tubing with ferrules.

Features:
  • Rao’s Bulk Cylinder Conversion Units that find application in efficiently connecting bulk cylinders to anesthesia apparatus
  • Available in 3675 – Oxygen option
  • Unit comprises –
    • 2 mtrs high pressure tubing with ferrules
    • Regulator
    • Pin index adaptor to fit on yoke of apparatus in place of service cylinder

» Cylinder Conversion Units - Nitrous Oxide

Image

Cylinder Conversion Units - Nitrous Oxide offered comprises Rao’s Bulk Cylinder Conversion Units and finds application in efficiently as well as accurately connecting bulk cylinders to anesthesia apparatus. We here are making it available in option of 3676 - Nitrous Oxide. The complete unit comprises 2 mtrs. High Pressure Tubing that comes with ferrules, Regulator as well as support of Pin Index Adaptor so as to fit on yoke of apparatus in place of service cylinder.

Features:
  • Rao’s Bulk Cylinder Conversion Units
  • Finding application in connecting bulk cylinder to anesthesia apparatus
  • Available in 3676 - Nitrous Oxide option
  • Unit comprises regulator, pin index adaptor to fit on yoke of apparatus in place of service cylinder and 2 mtrs high pressure tubing with ferrules

Our Clients

  • AIIMS, New Delhi
  • Breach Candy Hospital, Mumbai
  • Apollo Group of Hospitals
  • Medical Mission, Chennai
  • Bombay Hospital Trust, Mumbai
  • P.D. Hinduja Hospital, Mumbai

Company Address

Anaesthetics India Private Limited
Amar Business Center, Ram Mandir Road
Goregaon West, Mumbai - 400 104, MH, India
Email: salesaipl1951@gmail.com
Mobile: +(91) - 9820045383
Telephone: +(91)-(22)-66952980-84 /65229352

Products and Services